
Add to Cart
Metal Housing 60w 12v 5A Fanless Power Supply Auto Recovery Overload
12V 60W Slim Led Power Supply For Using In Led Strips 12v 5A LED Lights Signs
LED Signs 60w 12v
12v 5A CCTV Camera transformer
Metal housing LED power supply for indoor use. Also known as industrial power supplies,
these transformers are suitable for up to 24 hours of use.
Suitable for 12V or 24V led strip operation. It is important that the LED power supply is not overloaded,
up to a maximum of 80-85% of the rated power.
The power supply has a terminal block through which it can be connected to both the mains and the LED strip.
SPECIFICATION DETAILS
Model No. | JSGK-60-12 | JSGK-60-24 | |
Output | DC Voltage | 12V | 24V |
Current Range | 0~5A | 0~2.5A | |
Power | 60W | ||
Ripple And Noise | Max 150mVp-p | ||
Voltage Tolerance | ±5% | ||
Setup, Rise Time | 2000ms, 100ms / 230VAC | ||
Input | Voltage Range | 170~260VAC | |
Frequency Range | 50~60Hz | ||
Efficiency | >0.85 | ||
PF | 0.6 | ||
Current | 1.7A/220VAC | ||
Surge Current | 36A/220VAC | ||
Leakage Current | Max 1mA/240VAC | ||
Protection | Overload | Above 110%-150% of rated power | |
Shut-down output voltage, auto recovery after fault condition is removed | |||
Overvoltage | Above Max. Voltage (105% of rated voltage) | ||
Shut-down output voltage, auto recovery after fault condition is removed | |||
Over temperature | 90℃ ± 5℃(5~12V) 80℃ ± 5℃(24V) | ||
Shut-down output voltage, auto recovery after fault condition is removed | |||
Environment | Working Temp. & humidity | "-20°C~+60°C, 20%~90%RH | |
Storage Temp. & humidity | "-40°C~+85°C, 10%~95%RH | ||
Safety | Withstand Voltage | I/P-O/P: 1.5KVAC/1min; I/P-F/G: 1.5KVAC/1min; O/P-F/G: 0.5KVAC/1min; | |
Safety | GB4943 ;IEC60950-1; EN60950-1 | ||
EMC | EN55032:2015/AC:2016; EN61000-3-2:2014; EN61000-3-3:2013; EN55024:2010+A1:2015 | ||
LVD | EN60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 | ||
Other | Cooling | fanless | |
Lifespan | 20000hrs | ||
Dimensions (L*W*H) | 119*35*23mm | ||
Weight | 100g, 50pcs/ctn | ||
Note | 1. The above mentioned data were measured at 230VAC input and 25°C. | ||
2. Dis-connect the AC input before checking any mal-phenomenons. | |||
3. Make sure the INPUT&OUPUT were in right situation before connected to power supply. | |||
4. Datasheet for reference only. We suggest you take sampling before mass orders |
Packing:
White/brown or customized color box +Carton(double wall corrugated board); Wood case if necenarry.
Shipping:
1. FedEx / DHL / UPS / TNT for samples, Door-to-Door;
2. By Air freight or by Sea for large quantity, for FCL; Airport/ Port receiving;
3. Customers specifying freight forwarders or negotiable shipping methods!